+86-15123173615
DATAKOMD500 Genset Controller Universal Control Replacement For Deep Sea Series Diesel Generator
video
DATAKOMD500 Genset Controller Universal Control Replacement For Deep Sea Series Diesel Generator

DATAKOMD500 Genset Controller Universal Control Replacement For Deep Sea Series Diesel Generator

Genset Controller Universal Control Universal Control Replacement
Send Inquiry
Product Details ofDATAKOMD500 Genset Controller Universal Control Replacement For Deep Sea Series Diesel Generator

Chongqing Kyson Machinery Equipment Co., Ltd. is one of the leading manufacturers and suppliers of datakomd500 genset controller universal control replacement for deep sea series diesel generator in China. With abundant experience, our factory offer high quality products made in China with competitive price. Welcome to place an order.

 

Technical Specification & Payment and Trade Terms & Delivery and Packaging

Desc.

Genset Controller

Part No/TC type

DATAKOMD500

Brand Name

Man, ABB, PBS, KBB, Napier MET, Weicai, JTH

Other parts

pls contact freely
if you need other P/N

Engine Type

Diesel engine,Gas engine,
Diesel Generators etc.

Spare Type

Cartridge, Nozzle ring , shaft, rotor complete, compressor wheel, diffuser, turbine casing , compressor casing , bearing casing, turbine blades, bearing

Condition:

Original , brand new, OEM, replacement, refurbished

Applicable industry

Marine engines,
Construction works ,oil platform
Energy & Mining etc

Key Word:

Original spare parts
and engine repair tool kits

Trade terms

FOB EXW CIF DDU DDP,

Door to door is available in some countries.

Delivery time:

Most parts are in stock, bulk order based on qty

Payment

T/T, L/C,D/A, Alipay, Western Union, Paypal etc.

Place of origin

China/Germany/South Korea USA/Japan/Sweden /UK/Singapore/Taiwan

Package

Neutral or original packaging

About the product

Lightning Protection Measures
Diesel generator sets must be equipped with essential lightning protection systems. In particular, those directly connected to overhead distribution lines require comprehensive lightning protection measures in accordance with national standards and design specifications. Different protective measures should be implemented for generator insulation based on specific conditions.

For direct-connected motors with a single-unit capacity ranging from 300 kW to 1500 kW, overvoltage protection is achieved using the designated "9" protection wiring configuration. For high-voltage direct-connected motors with a single-unit capacity of 300 kW or less, the "10(a)" protection wiring or "10(b)" method is adopted depending on operational experience and specific circumstances. This involves installing a set of lightning arresters and capacitors at the line entry point, along with a protective gap on the pole near the entry point or grounding the iron foot of the insulator. For critical motors, the "9" protection wiring configuration is recommended.

For high-voltage rotating motors, magnetic-blowout lightning arresters are typically employed for lightning protection. These arresters should be installed as close as possible to the generator. Under normal operating conditions, they can be mounted at the motor's outgoing line. If no more than two generators are connected to each busbar, or if the single-unit capacity does not exceed 500 kW and the distance from the arrester does not exceed 50 meters, the arresters may also be installed on each busbar.

When the neutral point of a direct-connected motor can be led out but is not directly grounded, a magnetic-blowout or ordinary valve-type arrester should be installed at the neutral point. The rated voltage of the arrester must not be lower than the highest operating phase voltage of the generator. For generators with a line voltage of 6.3 kV, FCD-4 type or FZ-4 type 4 kV arresters should be selected; for 10.5 kV generators, FCD-6 type or FZ-6 type 6 kV arresters are recommended.

Inspection and Maintenance
During normal operation, the protective cover of the regulator must remain intact and should not be disassembled unless necessary. Comprehensive inspections and maintenance should be conducted every 200 hours of operation. Key tasks include:
1. Remove the protective shell and inspect the contact surfaces for dirt or burn damage. Clean the surfaces with a clean cloth if dirt is present. If erosion or unevenness compromises contact quality, smooth the surfaces using fine-grade sandpaper (e.g., "00" grade) and clean thoroughly afterward.
2. Verify the secureness of all connections and measure the resistance values of each coil. Replace or repair any damaged components promptly.
3. Test the closing voltage and reverse current of the circuit breaker, the limit voltage of the voltage regulator, the limit current of the current regulator, and the gaps between various contacts. Adjust these parameters as needed to meet technical specifications.
4. After inspection and adjustment, closely monitor the charging current meter during diesel engine startup. If the meter pointer remains in the "-" position at medium or higher engine speeds, it indicates that the circuit breaker contacts have not opened properly. Disconnect the grounding switch immediately to prevent damage to the battery, regulator, and charging generator. If the meter pointer remains at "0" after the diesel engine reaches its rated speed, it suggests that adjustments were not performed according to technical requirements. Reinspect and readjust as necessary.

Regulator Adjustment Method for Diesel Generator Sets
During the operation of diesel generator sets, common faults include the charging current meter pointer not moving, excessive or insufficient charging current. An excessively large charging current can shorten the battery's service life, while an overly small current may fail to charge the battery adequately. When the diesel engine is operational and the charging current meter indicates an excessive current, adjust the limit spring of the regulator to reduce its length. This will decrease the current; conversely, increasing the spring length will increase the current. Carefully adjust the position during the process, ensuring gentle handling until the requirements are met.