+86-15123173615

Special Action To Prevent Ship Mechanical And Electrical Equipment Malfunctions Case Analysis 74- Ship Generator Failure Unable To Start

Oct 19, 2024

The ship generator is the core of the ship, responsible for the important task of generating electricity for the entire ship and playing the role of the "heart". The operational reliability of ship generators plays an extremely important role in the normal operation of the system, the uninterrupted power supply of the ship, ensuring the quality of electrical energy, and even the safe operation of the entire ship. Its operational status plays a decisive role in the reliability and safety of ship operation. Once the ship's generator set fails, it is highly likely to cause damage to electrical equipment, and even lead to power loss and loss of control, causing accidents and dangerous situations.

 

Since April 7, 2024, the Maritime Safety Administration of the Ministry of Transport has launched a special action to prevent ship mechanical and electrical equipment failures nationwide, and the Sansha Maritime Safety Administration has solidly promoted this special action. Below is a typical case of a ship generator being unable to start and supply power normally due to damage to the coupling of the high-pressure oil pump camshaft. This case exposes the problem of inadequate maintenance and daily management of mechanical and electrical equipment for ships under 500 gross tons in accordance with regulations, as well as weak sense of responsibility among crew members. It is hoped that relevant shipping companies and ships will pay attention to this issue and strengthen investigation and self correction.

 

1, Basic information

The "J" ship is a general dry cargo ship in the near sea area, with a total tonnage of 499. The keel was laid on April 23, 2008, and the construction was completed on December 18, 2008. The engine compartment is equipped with two generators, with power of 50KW and 15KW respectively. The vessel was detained twice before August 2024 and has been listed as a "blacklist" vessel.

 

2, FSC inspection status

On August 7, 2024, security personnel from Sansha Maritime Bureau conducted a flag state safety supervision inspection on the "J" ship docked at Yongxing Port in Xisha, including a special inspection to prevent mechanical and electrical equipment failures of the ship. During the inspection process, it was found that the left generator was continuously used to generate electricity, and the right generator could not start normally. At the same time, the ship also had other serious defects, and the security personnel immediately detained the ship in accordance with the law.

 

The defect of the generator being unable to start discovered during this FSC inspection is typical and representative, and similar situations are commonly found in small vessels with a total tonnage of 499.

 

news-1080-821

Figure 1: The right generator lacks maintenance and cannot be started

 

3, Defect analysis

The ship inspection certificate held by the diesel generator of this round shows that the first generator set (left) is model T2X225L-4-H, with a rated power of 50kw and a prime mover model of 4135ACaf. The second generator set (right) is STC2-15H, with a rated power of 15kw and a prime mover model of L28M. The power difference between the two generators is significant. Based on the ship structure and equipment characteristics of this type of 499 ton small sea vessel, the security inspector analyzed that one large generator is usually used as a navigation generator, and the other small generator is used as a mooring generator. The small generator is the one with the problem with the high-pressure oil pump. The characteristic of such small sea vessels is poor maintenance of the hull and equipment. When the small generator breaks down and there is still a large generator that can be used, the crew does not go to repair it until the maritime security personnel arrive and take action.

 

After a detailed inspection by the security personnel, the reason why the right auxiliary engine of the wheel cannot be started is that the coupling of the high-pressure oil pump camshaft is broken. And the fracture lasted for more than a week, during which the wheel continued to operate using the left generator. The coupling of the camshaft of the high-pressure oil pump has to withstand considerable torque and stress during the daily operation of the oil pump. The material is generally steel, and the use of a wooden coupling for this wheel cannot meet the requirements of equipment operation.

 

news-1080-1440

Figure 2: Broken wooden coupling

 

According to Chapter 3.2 of Part 2-1 of the Technical Regulations for Inspection of Domestic Navigation Ships (2004), ships should be equipped with a main power supply for equipment use, which should consist of at least two generator sets. The number and capacity of these generator sets should be able to continue supplying power to equipment necessary for normal propulsion and ship safety even when any generator set stops working.

 

The coupling of the camshaft of the high-pressure oil pump of the generator is subjected to considerable torque and stress, and the wooden material is obviously not in compliance with the requirements. The wheel should purchase a qualified coupling as required and replace it on the camshaft of the high-pressure oil pump.

 

news-865-1153

Figure 3: Replacement of qualified coupling

 

4, Safety management suggestions

The coastal small boats with a total tonnage of 499 have always been the "hardest hit areas" for security checks and are also the key targets for the rectification of "large ships and small certificates". With the continuous strengthening of maritime supervision and ship inspection, the problem of mechanical and electrical defects in such ships has become prominent. Taking the "J" ship in this case as an example, its condition is very poor, lacking necessary maintenance and upkeep. The machinery and equipment are exhausted, and spare parts are missing.

 

For ships with a total tonnage of less than 500 tons, combined with the problems discovered during this security check, the following suggestions are proposed:

(1) Strengthen company management. The management company's established safety management systems should not be limited to general standards, but should fully consider the actual equipment configuration of the ship, ensure that each supporting equipment is maintained on a regular basis, and fully implement measures for ship navigation safety and pollution prevention.

(2) Strengthen shore based support. For the key mechanical and electrical equipment of ships, the company should conduct timely inspections, provide technical guidance, and reminders, and track existing safety hazards in a timely manner until they are eliminated.

(3) Enhance the crew's ability to perform their duties. We should urge shipping companies to continuously strengthen the education and training of crew members, enhance their safety awareness, improve their performance and emergency response capabilities, and abandon the idea and practice of "no need, no maintenance". At the same time, maritime departments should strengthen security checks and operational inspections of crew members, using administrative inspections to force crew members of small ships to consciously carry out ship maintenance and repair.

 