Oxidation catalyst, abbreviated as DOC. Its main function is to reduce carbon monoxide and hydrocarbons in engine emissions. Its main component is the oxidation catalyst. Compared with the other two technical routes, this one has fewer parts, simpler assembly and lower cost.

 

The vehicle is weak, but the urea consumption is normal

1. Common phenomenon: The car owner reports that the vehicle is weak, the urea consumption is normal, and when accelerating urgently, a small amount of white smoke can be found coming out of the muffler.

2. Analysis: The fault code read with a diagnostic instrument indicates that the engine emissions exceed the standard, and there are no other faults. After removing the urea nozzle and conducting a spray test with a diagnostic instrument, no abnormalities were found. During the inspection, it was discovered that a large amount of urea had crystallized and severely blocked the high-temperature catalytic tube. Therefore, the exhaust elbow was removed for cleaning, and the carbon soot adhering to the ceramic surface of the catalytic converter was cleaned with an air belt. The fault disappeared after the urea solution was replaced and the test run was conducted.

3. Summary: After the urea crystallization malfunctions, a large amount of urea accumulates inside the exhaust pipe, not only causing the engine's exhaust to be blocked and weak, but also leading to excessive emissions. After several driving cycles, the OBD torque is limited. The main reason is mostly due to the substandard quality of urea.

 

The urea pressure is too low, resulting in high urea consumption

1. Common phenomenon: The fault light on the vehicle's instrument panel flashes frequently, and the fault code shows that the urea pressure is too low and the urea consumption is high.

2. Analysis: The upper part of the urea tank of this vehicle is severely leaking. Even after replacing the urea tank assembly and the urea pump, there is still a leakage of urea solution. During the inspection, it was found that the leakage location was the vent hole of the urea tank. Rule out the possibility of excessive addition of urea solution and check the water heating valve of the urea tank. It was found that the water heating valve was constantly unblocked and damaged. The water heating valve was replaced and the fault was eliminated.

3. Summary: The excessively high temperature inside the urea tank causes the urea to volatilize. After being discharged through the vent hole, it crystallizes around the urea tank. Excessive crystallization in the vent hole causes the vent hole to be blocked. When the urea system is working, the vacuum inside the box is severely evacuated, and the urea pressure is blocked, so a fault of too low urea pressure is reported.

 

Insufficient power, excessive or insufficient urea consumption

1. Phenomenon: The fault light remains on constantly. Insufficient power, torque limit: 1800 RPM. The SCR system is not functioning properly, with urea consumption being either too high or too low.

2. Analysis: The fault codes read with a diagnostic instrument indicate that the voltage signal of the urea pump pressure sensor is high, actuator 2 is short-circuited to ground, the urea directional control valve actuator is open-circuited, and sensor power supply 3 is incorrect. After inspection of the power supply module of the urea pump, it was found that there was extensive corrosion, which caused the plug-in wiring harness inside the power supply module to be connected and transmitted incorrect voltage value signals to the ECU.

3. Summary: Replace the plugs of the urea pump and the power supply module. After the reinstallation, the urea fault code can be cleared when rechecked, but only the sensor power supply 3 cannot be cleared. Analysis of sensor power supply 3 refers to the internal power supply module of the ECU. Troubleshooting by replacing the rail pressure sensor.